ZEUS MINING
CRYPTO MINING PRO

Antminer S19j Pro pic_disable_dc_dc_common failed - S19j Pro Kernel Log

Created 2022/12/30 

A miner reported that after his Antminer S19j Pro ran for a while, the log showed pic_disable_dc_dc_common failed (as shown in the figure below). After checking the log, our technicians found that the PIC failed to open the DCDC circuit, which caused the miner to fail to complete the initialization.

S19j Pro pic disable 

Solution:

For this failure, you can troubleshoot according to the following steps:

1. Check whether the hash board cable is loose or damaged.

2. Use a programmer to rewrite the PIC program.

3. Check the output of the PIC chip (the normal voltage is around 3.3V), and replace the PIC chip if the voltage is abnormal.

0
Customer Service